Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 687-691-8 | CAS number: 709031-43-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Between 07 February and 15 March 2012.
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 012
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Version / remarks:
- - using the shake-flask method, designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 107 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Version / remarks:
- using the shake-flask method, designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 107 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
Test material
Reference
- Name:
- Unnamed
- Type:
- Constituent
- Details on test material:
- Identification: BMS-528235-01
Description: Off white powder
Batch: 1L63487N
Purity: 98.6 %
Expiry Date: 27 November 2014
Storage Conditions: Room temperature in the dark
Results and discussion
Partition coefficient
- Type:
- log Pow
- Partition coefficient:
- 77.2
- Temp.:
- 23 °C
- Remarks on result:
- other: The partition coefficient of the test item has been determined to be 77.2 at 23.0 ± 1.5 °C, log10 Pow 1.89. Testing was carried out at approximately neutral pH with the test item in a non-ionised form.
- Details on results:
- Due to the tabular nature of this information & to retain the integrity & coherence of the original Harlan Laboratories Ltd. Study report please see section “Any other information on results incl. tables”
Any other information on results incl. tables
Results
Preliminary assessment
The log10Powwas calculated to be 2.53.
The full KOWWIN calculation is presented in Appendix 3 (Attachment 2).
Please see Attachment 3 for the Typical Chromatography.
The mean peakareasobtained for the standard, stock and sample solutions are shown in the following two tables:
Table 3.14– Organic Phase
Solution |
Mean PeakArea |
Standard 46.8 mg/L |
1.3286 x 107 |
Standard 41.2 mg/L |
1.1477 x 107 |
Sample 1 |
1.0698 x 107 |
Sample 2 |
1.0613 x 107 |
Sample 3 |
1.0489 x 107 |
Sample 4 |
1.0494 x 107 |
Sample 5 |
1.0647 x 107 |
Sample 6 |
1.0828 x 107 |
Stock solution A |
1.0777 x 107 |
Stock solution B |
1.0869 x 107 |
Table 3.15– Aqueous Phase
Solution |
Mean PeakArea |
Standard 10.3 mg/L |
2.8336 x 106 |
Standard 10.2 mg/L |
2.8922 x 106 |
Sample 1 |
2.9865 x 106 |
Sample 2 |
3.0493 x 106 |
Sample 3 |
3.0080 x 106 |
Sample 4 |
2.8994 x 106 |
Sample 5 |
3.1892 x 106 |
Sample 6 |
2.9993 x 106 |
The total weights (mg) and analysed concentration (mg/L) of the respective phases are shown in the following table:
Table 3.16
Sample Number |
Organic Phase |
Aqueous Phase |
% Recovery |
|||
Analysed Concentration (mg/L) |
Weight (mg)† |
Analysed Concentration (mg/L) |
Weight (mg)† |
pH |
||
1 |
3.88 x 103 |
291 |
50.3 |
3.77 |
7.3 |
100 |
2 |
3.86 x 103 |
289 |
49.8 |
3.73 |
7.3 |
99.6 |
3 |
3.82 x 103 |
145 |
50.1 |
3.81 |
6.2 |
99.9 |
4 |
3.82 x 103 |
176 |
50.9 |
4.69 |
6.9 |
100 |
5 |
3.87 x 103 |
348 |
48.7 |
2.19 |
7.0 |
99.2 |
6 |
3.92 x 103 |
298 |
50.2 |
1.91 |
6.9 |
101 |
pH of n-octanol saturated water: 7.5
Temperature: 23.0 ± 1.5
°C
The partition coefficient determined for each sample is shown in the following table:
Table 3.17
Sample Number |
Organic/Aqueous Volume Ratio |
Partition Coefficient |
Log10Pow |
Mean Partition Coefficient |
1 |
1:1 |
77.2 |
1.89 |
77.3 |
2 |
77.4 |
1.89 |
||
3 |
1:2 |
76.2 |
1.88 |
75.6 |
4 |
75.0 |
1.88 |
||
5 |
2:1 |
79.4 |
1.90 |
78.8 |
6 |
78.2 |
1.89 |
Mean Pow: 77.2 log10Pow: 1.89 Powstandard deviation : 1.53
† From analysis of the respective phase
Validation
Organic phases: The linearity of the detector response with respect to concentration was assessed over the concentration range of 0 to 114 mg/L. This was satisfactory with a correlation coefficient (r2) of 1.000 being obtained.
Aqueous phases: The linearity of the detector response with respect to concentration was assessed over the concentration range of 0 to 23.3 mg/L. This was satisfactory with a correlation coefficient (r2) of 1.000 being obtained.
Applicant's summary and conclusion
- Conclusions:
- The partition coefficient of the test item has been determined to be 77.2 at 23.0 ± 1.5 °C, log10 Pow 1.89.
- Executive summary:
The determination was carried out using the shake-flaskthod, designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 107 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.
Conclusion
The partition coefficient of the test item has been determined to be 77.2 at 23.0±1.5°C, log10 Pow 1.89.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.