Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: basic data given

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
DIN EN ISO 13736
Deviations:
no
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Decanter Oil
IUPAC Name:
Decanter Oil
Constituent 2
Reference substance name:
Aromatic hydrocarbons, >C5, reclaimed, waste tars and tar oils and tar pitches
IUPAC Name:
Aromatic hydrocarbons, >C5, reclaimed, waste tars and tar oils and tar pitches
Details on test material:
- Name of test material (as cited in study report): Decanter Oil

Results and discussion

Flash point
Flash point:
55 °C
Atm. press.:
ca. 101 kPa
Remarks on result:
other: -

Applicant's summary and conclusion

Conclusions:
Flam. Liquid 3 according to CLP-regulation