Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Nov 2014 - Feb 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes
Key result
Remarks on result:
no self-ignition observed up to the melting point
Conclusions:
The self-ignition temperature of the test substance was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device.
Based on the results obtained the test substance is considered ‘not self-ignitable’.

Description of key information

The self-ignition temperature of the test substance was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device.

Based on the results obtained the test substance is considered ‘not self-ignitable’.

Key value for chemical safety assessment

Additional information