Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 June 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test method according to EEC A.9. GLP study.
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Key result
Flash point:
> 200 °C
Remarks on result:
other: No flash point up to the boiling point. Flash point higher than 200 ºC.

Results:

Preliminary test

Test No.1

Temperature [°C]

Result

Temperature [°C]

Result

24

-

150

-

27

-

152

-

30

-

154

-

33

-

156

-

36

-

158

-

39

-

160

-

42

-

162

-

45

-

164

-

48

-

166

-

51

-

168

-

54

-

170

-

57

-

172

(-)1

60

-

174

(-)1

63

-

176

(-)1

66

-

178

(-)1

69

-

180

(-)2

72

-

182

(-)2

75

-

184

(-)2

78

-

186

(-)2

81

-

188

(-)2

83

-

190

(-)2

86

-

192

(-)2

89

-

194

(-)2

92

-

196

(-)2

95

-

198

(-)2

98

-

200

(-)2

101

-

 

104

-

 

107

-

 

110

-

 

114

-

 

118

-

 

122

-

 

126

-

 

130

-

 

134

-

 

138

-

 

142

-

 

146

-

 

150

-

 

154

-

 

158

-

 

162

-

 

166

-

 

170

(-)1

 

174

(-)1

 

178

(-)1

 

182

(-)2

 

186

(-)2

 

190

(-)2

 

194

(-)2

 

198

(-)2

 

200

(-)2

 

(+): yes

(-): no

(-)1: sample vapors extinguish the flame

(-)2: boiling of sample

Conclusions:
No flash point was observed up to the boiling point. The flash point of test item is higher than 200 ºC under the test conditions.
Executive summary:

Determination of flash point of the test item was performed according to standard PN-EN ISO 2719: 2007 ”Determination of flash point – Pensky-Martens closed cup method.” in accordance with EEC A.9. No flash point was observed up to the boiling point. The flash point of test item is higher than 200 ºC under the test conditions.

Description of key information

Key study: Test method EEC A.9, GLP study. No flash point was observed up to the boiling point. The flash point of test item is higher than 200 ºC.

Key value for chemical safety assessment

Additional information

Key study: Determination of flash point of the test item was performed according to standard PN-EN ISO 2719: 2007 ”Determination of flash point – Pensky-Martens closed cup method.” in accordance with EEC A.9. No flash point was observed up to the boiling point. The flash point of test item is higher than 200 ºC under the test conditions.