Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Remarks:
Other density types indicated (migrated information): density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 February 2011 – 27 April 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and in compliance with GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
(1995)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
(Official Journal of the European Union no. L142, May 31, 2008)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: gas comparison pycnometer (for solids)

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): E-Y110
- Test substance storage: At room temperature protected from light
- Stability under storage conditions: Stable
- Description: Orange powder
- Batch: MB-1
- Expiry date: 23 December 2015

Results and discussion

Densityopen allclose all
Type:
density
Density:
1.71 g/cm³
Temp.:
20 °C
Type:
relative density
Density:
1.71

Any other information on results incl. tables

Calibration values obtained were within the NOTOX criteria range (see table below).

 

 

[cm3]

 

 

criteria

 

Reference volume

Sample chamber volume

Vessel volume

 23.27

41.89

6.24

23.41 ± 0.23 cm3

41.91 ± 0.42 cm3

6.26 ± 0.06 cm3

The results of the tests on the determination of the density of the test substance are given in the Table below.

 

Test 1

Test 2

Mean

Density [g/cm3]

1.710

1.709

1.71

The individual measurements were obtained with an accuracy of <0.02 g/cm3. According to the guideline, the density of the test substance is given as the mean value.

Applicant's summary and conclusion

Conclusions:
A gas comparison pycnometer was used for the determination of the density and relative density of E-Y110. The density of the test substance at 20ºC was 1.71 g/cm3 (1.71 x 10^3 kg/m3). The relative density was 1.71.