Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The flash point of the test item was determined according to the NF EN ISO 3679 and the NF EN ISO 2719 methods.No flash point was observed with any of the two methods.The test item is not classified as flammable liquid, but vapours that are generated by the test item can lead to an explosive atmosphere (ATEX) when in mixtures with air in confined spaces.

Key value for chemical safety assessment

Additional information

The test item is not classified as flammable liquid