Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Principles of method if other than guideline:
The substance was investigated according to the Grewer test/ oven.
GLP compliance:
no
Key result
Remarks on result:
other: does not undergo spontaneous combustion before melting

No exothermic effects were determined up to the point at which the test substance melted (ca 90 °C). The wire mesh basket was empty after the measurement.

Conclusions:
The test substance does not undergo spontaneous combustion before melting.
Executive summary:

According to Grewer test the test substance does not undergo spontaneous combustion before melting.

Description of key information

The test substance does not undergo spontaneous combustion before melting.

Key value for chemical safety assessment

Additional information

The test substance does not undergo spontaneous combustion before melting.