Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guideline study according to GLP principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
oscillating densitimeter

Test material

Results and discussion

Density
Type:
relative density
Density:
1.113
Temp.:
20 °C
Remarks on result:
other: water at 4°C as reference

Applicant's summary and conclusion

Conclusions:
result of relative density shows 1.1128 at 20 °C and water at 4 °C as refrence