Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
According to the standard but only one temperature, and it is not GLP
Qualifier:
according to guideline
Guideline:
other: JIS Z 8803
Deviations:
no
Principles of method if other than guideline:
This standard method is applied to measure viscosity by Brookfield type (BM type and BL type rotator viscometer)
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
> 100 - < 400
Executive summary:

The dynamic viscosity was measured by rotational viscometer. Viscosity at 20ºC is 180 mPa*s (sales specifications of the substance: 100-400).

Description of key information

Slightly viscous liquid.

Key value for chemical safety assessment

Viscosity:
180 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

An experimental study is provided on the measurement of dynamic viscosity.