Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
According to the standard but only one temperature, and it is not GLP
Qualifier:
according to guideline
Guideline:
other: JIS Z 8803
Deviations:
no
Principles of method if other than guideline:
This standard method is applied to measure viscosity by Brookfield type (BM type and BL type rotator viscometer)
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
> 100 - < 400
Executive summary:

The dynamic viscosity was measured by rotational viscometer. Viscosity at 20ºC is 180 mPa*s (sales specifications of the substance: 100-400).

Description of key information

Slightly viscous liquid.

Key value for chemical safety assessment

Viscosity:
180 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

An experimental study is provided on the measurement of dynamic viscosity.