Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 479-930-8 | CAS number: 613222-52-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2004-10-06 to 2004-12-17
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
- Version / remarks:
- 1988
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Version / remarks:
- 1984
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION
- Method:
For the pre-test, a stock solution containing 200 mg test item/L in deionized water was prepared. After 10 minutes in the ultrasonic bath the emulsion didn’t show any undissolved particles. The stock solution then was used to prepare solutions at the concentrations of 100, 10, and 1 mg/L. Because of the low water solubility, the treatment of 1000 mg/L was prepared by adding the appropriate volume of the test item directly.
In the main study, the test item was used directly. - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: The sludge was taken from the activation basin of the ESN (Stadtentsorgung Neustadt) sewage treatment plant, Im Altenschemel, 67435 NW-Lachen-Speyerdorf.
- Pretreatment: The sludge was washed with tap water three times, then centrifuged and resuspended in tap water. 200 ml of the sludge were added to each test vessel.
- Initial biomass concentration: 4.1 g suspended solids/litre - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Test temperature:
- 20 ± 2 °C
- pH:
- 7.4 (control)
- Nominal and measured concentrations:
- Pre-test: Nominal concentrations: 1, 10, 100, 1000 mg/L of test item
Main test: 1000 mg/L of test item - Details on test conditions:
- TEST SYSTEM
- Test vessel: glass beakers as test vessels; narrow-neck glass with flat bottom as measuring flasks
- fill volume: 500 mL
- Aeration: purified air, using Pasteur pipettes, flow approx. 0.75 L/min.
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): two replicates before, two between and two after measuring O2-concentrations in the reference and test item replicates
- Sludge concentration: 1.64 g suspended solids/L in the main test
EFFECT PARAMETERS MEASURED:
- O2-consumption
- pH value at the beginning of the O2-measurement
TEST CONCENTRATIONS
- Range finding study
- Test concentrations: 0, 1, 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: No inhibition was observed at 1000 mg/L. - Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Duration:
- 3 h
- Dose descriptor:
- other: EC20
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Details on results:
- Two valid experiments were performed.
In the pre-test, the test item was tested using four concentrations (ranging from 1000 to 1 mg/L). Duration of the test was three hours. Activated sludge was used as inoculum. It was taken from a domestic sewage treatment plant and washed before usage. The dry matter was determined as 4.0 g suspended solids/L, giving a concentration of 1.6 g sus-pended solids/L in the test. As the pre-test was performed for range-finding only, no reference item was tested.
No inhibition of the respiration of the activated sludge was detected in the treatments.
The main study was performed as a limit-test with a nominal concentration of 1000 mg/L. Conduct of the study was the same as in the pre-test. The dry matter of the activated sludge was determined as 4.1 g suspended solids/L, giving a concentration of 1.64 g suspended solids/L in the test. No inhibition was observed. - Results with reference substance (positive control):
- 3,5-Dichlorophenole was used as reference item. The EC50 of the reference item was determined as 8.2 mg/L (95% confidence interval: 6.4 – 10.2 mg/L), which lies within the recommended range of 5 – 30 mg/L.
- Validity criteria fulfilled:
- yes
- Conclusions:
- Sika HardenerLH was tested for toxicity to aquatic micro-organisms in a 3 h-activated sludge respiration inhibition test according to EU method C.11.
The following results could be determined for the test item Sika Hardener LH (VP) (species: activated sludge from a domestic sewage treatment plant):
3h NOEC = 1000 mg/L
3h EC20 > 1000 mg/L
3h EC50 > 1000 mg/L - Executive summary:
Sika Hardener LH was assessed in an activated sludge respiration inhibition test, according to the EU-method C. 11 and OECD guideline 209. Two valid experiments were performed. In the pre-test, the test item was tested using four concentrations (ranging from 1000 to 1 mg/L). Duration of the test was three hours. Activated sludge was used as inoculum. It was taken from a domestic sewage treatment plant and washed before usage. The dry matter was determined as 4.0 g suspended solids/L, giving a concentration of 1.6 g suspended solids/L in the test. As the pre-test was perforned for range-finding only, no reference item was tested.
No inhibition of the respiration of the activated sludge was detected in the treatments.
The main study was performed as a limit test with a nominal concentration of 1000 mg/L. Conduct of the study was the same as in the pre-test. The dry matter of the activated sludge was determined as 4.1 g suspended solids/L, giving a concentration of 1.64 g suspended solids/L in the test.
3,5 -Dichlorophenole was used as reference item. The EC50 of the reference item was determined as 8.2 mg/L (95 % CL: 6.4 - 10.2 mg/L), which lies within the recommended range of 5 - 30 mg/L.
The following results could be determined for the test item Sika Hardener LH (VP)(species: activated sludge from a domestic sewage treatment plant):
3h NOEC = 1000 mg/L
3h EC20 > 1000 mg/L
3h EC50 > 1000 mg/L
Reference
Pre-Test
O2-Consumption
No. |
Content |
Nominal Concentration in mg/L |
O2Consumption in mg/(L*min.) |
O2consumption in mg/(L*h) |
1 |
Control |
0 |
0.4119 |
24.71 |
2 |
Test Item |
1000 |
0.4352 |
26.11 |
3 |
Test Item |
100 |
0.4268 |
25.61 |
4 |
Test Item |
10 |
0.3861 |
23.17 |
5 |
Test Item |
1 |
0.3704 |
22.22 |
6 |
Control |
0 |
0.4486 |
26.92 |
Inhibition in %
Item |
Nominal Concentration (mg/L) |
Inhibition in % |
Test Item |
1000 |
-1.2 |
Test Item |
100 |
0.8 |
Test Item |
10 |
10.3 |
Test Item |
1 |
13.9 |
Main Study
O2-Consumption
No. |
Content |
Nominal Concentration (mg/L) |
O2consumption in mg/(L*min.) |
Mean O2cons. in mg/(L*min.) |
Mean O2cons. in mg/(L*h) |
1 |
Control |
0 |
0.9702 |
0.9292 |
55.7534 |
2 |
Control |
0 |
0.8883 |
||
3 |
Reference |
2.5 |
0.7419 |
0.6991 |
41.9471 |
4 |
Reference |
2.5 |
0.6563 |
||
5 |
Reference |
5 |
0.5867 |
0.6125 |
36.7471 |
6 |
Reference |
5 |
0.6383 |
||
7 |
Reference |
10 |
0.4191 |
0.4363 |
26.1800 |
8 |
Reference |
10 |
0.4536 |
||
9 |
Reference |
20 |
0.3127 |
0.3257 |
19.5416 |
10 |
Reference |
20 |
0.3386 |
||
11 |
Reference |
40 |
0.1634 |
0.1599 |
9.5416 |
12 |
Reference |
40 |
0.1556 |
||
13 |
Control |
0 |
0.7520 |
0.7271 |
43.6274 |
14 |
Control |
0 |
0.7022 |
||
15 |
Test Item |
1000 |
0.9058 |
1.0110 |
60.6569 |
16 |
Test Item |
1000 |
1.1161 |
||
17 |
Control |
0 |
1.0116 |
0.9983 |
59.8994 |
18 |
Control |
0 |
0.9850 |
The control vessels no. 13 and 14 were stated as outliers and were not used for the determination of the results, since the O2-consumption was much lower than in the other control vessels.
Inhibition of the O2consumption was calculated by comparison with the controls and is given in the following table:
Item |
Nominal Concentration (mg/L) |
Inhibition in % |
Test Item |
1000 |
-4.9 |
Reference |
2.5 |
27.5 |
Reference |
5 |
36.5 |
Reference |
10 |
54.7 |
Reference |
20 |
66.2 |
Reference |
40 |
83.4 |
Description of key information
Sika Hardener LH was assessed in an activated sludge respiration inhibition test, according to the EU-method C. 11 and OECD guideline 209. The 3-hour EC50 was determined to be greater than 1000 mg/L and the 3-hour NOEC determined at 1000 mg/L.
Key value for chemical safety assessment
- EC10 or NOEC for microorganisms:
- 1 000 mg/L
Additional information
Sika Hardener LH was assessed in an activated sludge respiration inhibition test, according to the EU-method C. 11 and OECD guideline 209. Two valid experiments were performed. In the pre-test, the test item was tested using four concentrations (ranging from 1000 to 1 mg/L). Duration of the test was three hours. Activated sludge was used as inoculum. It was taken from a domestic sewage treatment plant and washed before usage. The dry matter was determined as 4.0 g suspended solids/L, giving a concentration of 1.6 g suspended solids/L in the test. As the pre-test was perforned for range-finding only, no reference item was tested.
No inhibition of the respiration of the activated sludge was detected in the treatments.
The main study was performed as a limit test with a nominal concentration of 1000 mg/L. Conduct of the study was the same as in the pre-test. The dry matter of the activated sludge was determined as 4.1 g suspended solids/L, giving a concentration of 1.64 g suspended solids/L in the test.
3,5 -Dichlorophenole was used as reference item. The EC50 of the reference item was determined as 8.2 mg/L (95 % CL: 6.4 - 10.2 mg/L), which lies within the recommended range of 5 - 30 mg/L.
The following results could be determined for the test item Sika Härter LH (VP)(species: activated sludge from a domestic sewage treatment plant):
3h NOEC = 1000 mg/L
3h EC20 > 1000 mg/L
3h EC50 > 1000 mg/L
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.