Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

According to structural properties, hydrolysis is not expected/probable.

Key value for chemical safety assessment

Additional information

Due to the low water solubility (< 0.0003 mg/L) the study on Hydrolysis as a function of pH according to EEC directive 84/449 C.10 (CIBA-GEIGY 1992a) was technically not feasible. According to Annex VIII of the Regulation (EC) No 1907/2006 REACH, it is suggested, that a study on the "Hydrolysis as function of pH" does not need to be conducted if the "Substance is highly insoluble in water or if the substance is readily biodegradable". Due to the low solubility of the test substance data on hydrolysis are not provided.

Additionally, based on the chemical structure of the molecule hydrolysis of the test substance is not expected due to missing functional groups liable to hydrolysis.