Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-09-24 to 2012-10-29
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
adopted 12 May 1981
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
forced ball viscometer (dynamic)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
78.6
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
31.1

Table 1: Measured viscosity of SIKA Hardener LJ at 20°C

Properties of the ball

Density of Test Item, (g/cm3)

Falling time (sec)

Dynamic Viscosity (mPa*s)

Number

3

0.9236

 

66.22

78.6

65.94

78.3

Density, g/cm3

8.108

66.34

78.8

66.37

78.8

Constant mPa*sec*cm3/(g*sec)

0.16528

66.31

78.7

66.16

78.6

Mean

78.6

RSD

0.2 %

 

Table 2: Measured viscosity of SIKA Hardener LJ at 40°C

Properties of the ball

Density of Test Item, (g/cm3)

Falling time (sec)

Dynamic Viscosity (mPa*s)

Number

3

0.9236

 

26.16

31.1

26.03

31.0

Density, g/cm3

8.108

26.09

31.0

26.07

31.0

Constant mPa*sec*cm3/(g*sec)

0.16528

26.22

31.2

26.12

31.1

Mean

31.1

RSD

0.3%

 

Conclusions:
The dynamic viscosity of SIKA Hardener Lj was determined to be 78.6 mPa*sec at 20 °C and 31.1 mPa*s at 40 °C respectively.
Executive summary:

A study was conducted according to OECD TG 114 to determine the dynamic viscosity of SIKA Hardener LJ. Using the Höppler Viscometer and ultrapure water as reference the viscosity of SIKA Hardener LJ was determined at 20 °C and 40 °C. Two times three replicate measurements were performed at each temperature. The dynamic viscosity of SIKA Hardener LJ was determined to be 78.6 ± 0.002 mPa*s at 20 °C and 31.1 ± 0.003 mPa*s at 40 °C, respectively.

Description of key information

The dynamic viscosity of SIKA Hardener LJ was determined to be 78.6 mPa*s at 20 °C and 31.1 mPa*s at 40 °C, respectively.

Key value for chemical safety assessment

Viscosity:
78.6 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

A study was conducted according to OECD TG 114 to determine the dynamic viscosity of SIKA Hardener LJ. Using the Höppler Viscometer and ultrapure water as reference the viscosity of SIKA Hardener LJ was determined at 20 °C and 40 °C. Two times three replicate measurements were performed at each temperature. The dynamic viscosity of SIKA Hardener LJ was determined to be 78.6 ± 0.002 mPa*s at 20 °C and 31.1 ± 0.003 mPa*s at 40 °C, respectively.