Biodegradation in water: screening tests

Sika Härter LJ is not readily biodegradable but considered to be inherently biodegradable.

Additional information

Sika Härter LJ was tested for ready biodegradability in the Manometric Respirometry Test according to OECD guideline 301F and EU method C.4.

The test item can be considered as "not readily biodegradable". The degree of biodegradation reached 30% after 28 days. The 10 d-window began on day 5 and 25% were reached at its end, staying below the pass level of 60% degradation based on oxygen consumption. However, Sika Härter LJ is considered to be inherently biodegradable.