Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No guideline is mentioned, but performed according to rotational viscosimeter method according to OECD Guideline 114
Principles of method if other than guideline:
According to Brookfield viscosimeter
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Temp.:
other: 26.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
5
Remarks on result:
other: 5 cP

Description of key information

5 mPa*s at 26°C

Key value for chemical safety assessment

Additional information

The dynamic viscosity of the substance 1,3-butylene diacetate (CAS 1117 -31 -3) was determined by Brookfield viscosimeter.