Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Flammability

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The preliminary screening test was performed for the determination of the flammability of AXION ZR 9038.

The flame of the gas burner did ignite the test substance pile. The test substance melted, burned with a blue orange flame, emitted sparks and turned into a black charred residue. black smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed.

No propagation of combustion of the test substance along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test substance is considered ‘not highly flammable’.

Justification for classification or non-classification

No effects of combustion where noted.