Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with plenty of water. Seek immediate medical
attention.
Emergency measure - Skin: Wash affected area with plenty of water. If irritation
persists seek medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, carbon dioxide or dry powder may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,
nitrogen and sulfur and possibly hydrogen cyanide gas.

Product determined by test: N

Protective equipment: Full protective clothing and a self-contained breathing
apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.3.1). Take up spill
using suitable absorbent material. Transfer to labelled
containers and dispose of by incineration in accordance with
local regulations. Ventilate and wash spill site with water.

Avoid discharge to watercourses.

Handling and storage

Handling: Ensure adequate ventilation. A PVC full air suit should be
worn together with rubber gloves and compressed air-fed
respirators with full air hood. Hands and face should be
washed thoroughly after handling.

Storage: Store in tightly closed containers out of direct sunlight in
a cool place.

Packaging of the substance and or preparation: Store in a tightly closed UN approved container.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for reuse is not economically feasible.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility. Waste gas
treatment to remove oxides of nitrogen and sulfur should be
fitted. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.