Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP complaint, guideline study, available as unpublished report acceptable without restrictions.
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Principles of method if other than guideline:
The method used is based on a procedure designed to comply with that given in 'Particle size distribution, fibre length and diameter distribution', June 1996 European Commission technical guidance document, which satisfies the requirements of OECD Guideline 110.
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
No.:
#1
Size:
< 100 µm
Distribution:
17.6 %
Remarks on result:
other:
Remarks:
the proportion of potassium dicyanoaurate < 100 μm was 17.6%.

The results of the sieving procedure are shown below:

 Measurement

Result 

Mass of test item transferred to sieve 

10.24g

 Mass of test item passed through sieve

1.80g

Proportion of test item <100µm 

17.6%
Conclusions:
In an OECD Granulometry screening test the proportion of potassium dicyanoaurate < 100 μm was 17.6%.
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. the proportion of potassium dicyanoaurate < 100 μm was 17.6%

Description of key information

The proportion of potassium dicyanoaurate < 100 μm was 17.6%. 

Additional information

A GLP-compliant, guideline study is available for this endpoint (Harlan Laboratories 2011) and is considered suitable for use as the key study.

The dustiness of kaliumgoldcyanid was tested in a modified Heubach procedure according to standard guideline (Selck and Parr 2012). atmosphere. The total dustiness of kaliumgoldcyanid was determined to be 358.82 mg/g (35.9%). The inhalable fraction was 210.76 mg/g (47.2%), the thoracic fraction was 18.54 mg/g (0.09%) and the respirable fraction was 0.86 mg/g (0.03%). The Mass Median Aerodynamic Diameter (MMAD) was determined to be 29.0 μm with a geometric standard deviation of 1.7 μm.