Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not specified
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: GEMO PPH-300-00 : laser granulometry laser
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
Reverse Fourier Optic
Principles of method if other than guideline:
Guideline method adapted to substance hazard to avoid laboratory technicians exposure.
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: without anticaking agent
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
[(2-chlorophenyl)methylene]malononitrile
EC Number:
220-278-9
EC Name:
[(2-chlorophenyl)methylene]malononitrile
Cas Number:
2698-41-1
Molecular formula:
C10H5ClN2
IUPAC Name:
[(2-chlorophenyl)methylene]malononitrile
impurity 1
Reference substance name:
unknown impurities
Cas Number:
Not applicable
Molecular formula:
Not applicable
IUPAC Name:
unknown impurities
Test material form:
solid
Specific details on test material used for the study:
Item : "Poudre de CS – sans anti-mottant" from ALSETEX
Batch not specified
Storage not specified

Results and discussion

Mass median aerodynamic diameter:
ca. 302.2 µm
Geometric standard deviation:
256
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
ca. 111.5 µm
St. dev.:
256
Key result
Percentile:
D50
Mean:
ca. 302.2 µm
St. dev.:
256
Key result
Percentile:
D90
Mean:
ca. 682.3 µm
St. dev.:
256
Particle size distribution at different passages
Remarks on result:
not measured/tested

Applicant's summary and conclusion

Conclusions:
The mass median aeodynamic diameter of the substance item is 302.2 µm
Executive summary:

In a study according to GEMO PPH-300-00 methodology (laser granulometry laser), the mass median aeodynamic diameter of the substance item is 302.2 µm