EC number: 222-103-1 | CAS number: 3349-36-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
Description of key information
The flash point of the test material has been determined to be 71.3 °C at 769.7 mm Hg, using a manual Pensky-Martens closed-cup apparatus, in a study carried out in accordance with the testing standard ASTM D93-13 “Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester”.
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 71.3 °C
Additional information
A reliability rating of 1 was assigned to the key study, Finkelshtein (2014), according to the criteria of Klimisch et al. (1997). The supporting study, Atwal & Tremain (2010), was assigned a reliability rating of 3 in accordance with the criteria set forth by Klimisch et al. (1997).
The key study was selected on the basis that the value obtained was deemed to be more consistent with experience of the chemical in use. It is considered that contract research organisations usually run such determinations as serial examinations, preparing sample cups with samples to be tested in advance and placing them in a queue. When this test material is left standing open, the humidity of ambient air will react with the material to liberate butanol. As a result of this, values lower than the true flash point of the substance may be seen, resulting in a “false positive” being obtained. This effect is more pronounced with a small sample size and a longer queuing time.
As it can be seen that inadequate handling of the test material may affect the flashpoint data by producing artificially low values, it can be concluded that when a determination gives a higher flashpoint value, it is more reliable than that giving a lower one.
In the key study, the flash point of the test material was investigated in a study carried out in accordance with the testing standard ASTM D93-13 “Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester”.
The test was conducted using manual Pensky-Martens closed-cup apparatus. A brass test cup of specified dimensions was filled to the inside mark with the test material and fitted with a cover of specified dimensions. It was then heated and the test material stirred at a specified rate. An ignition source was directed into the test cup at regular intervals with simultaneous interruption of the stirring until a flash was detected.
Under the conditions of this study the flash point of the test material was determined to be 71.3 °C at 769.7 mm Hg.
In the supporting study, the flash point of the test material was determined to be 54 ± 2 °C,using a closed cup equilibrium method, designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.