Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04-04-2006 to 06-04-2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted under GLP conditions in accordance with the official OECD guideline No 121 (2001).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Version / remarks:
(January 2001)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Version / remarks:
(August 2001)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge

Test material

1
Chemical structure
Reference substance name:
p,p'-(2-pyridylmethylene)bisphenol
EC Number:
210-039-7
EC Name:
p,p'-(2-pyridylmethylene)bisphenol
Cas Number:
603-41-8
Molecular formula:
C18H15NO2
IUPAC Name:
4-[(4-hydroxyphenyl)(pyridin-2-yl)methyl]phenol
Test material form:
solid
Radiolabelling:
no

Study design

Test temperature:
20 to 25°C

HPLC method

Details on study design: HPLC method:
EQUIPMENT- Apparatus: Balance: Mettler XP205DR; pH meter: Metrohm 692 with Metrohm electrode 6.0258.000; HPLC equipment: Varian autosampler ProStar 410, Varian pump ProStar 230, Varian UV/VIS detector 310, Jones column oven 7990- Type: Varian autosampler ProStar 410; Varian pump ProStar 230 - Type, material and dimension of analytical (guard) column: Jones column oven 7990; column: LiChrospher 100 CN, particle size 5 µm, 250 mm*4mm; pre-column: CN- Detection system: Varian UV/VIS detector 310; Test item: 274 nm; Reference item: 210 nm; Sodium nitrate: 210MOBILE PHASES- Type: methanol/water (55:45; v/v) - pH: adjusted to pH 7.0 (using sodium hydroxide)- Solutes for dissolving test and reference substances: LA 96 was dissolved in a solvent mixture of methanol and water (55:45 v/v); the stock solutions of the reference items were dissolved in methanol.DETERMINATION OF DEAD TIME- Method: The dead time to was mesured by using an unretained compound (sodium nitrate) which was included in the mix of the reference items.REFERENCE SUBSTANCES- Identity: Acetanilide; Isoproturon; Linuron; Pyrazophos; Diclofop-methyl; 2,4-DDTREPETITIONS- Number of determinations: 3EVALUATION- Calculation of capacity factors k': k' = (tr - t0) / t0t0 = retention timestr = dead time- Determination of the log Koc value: the log k' values were plotted against the log Koc of the reference items using linear regression yielding the following equation: slope = 0.155; y-axis intercept = 0.025; coefficient of regression (r) = 0.999

Results and discussion

Adsorption coefficientopen allclose all
Type:
log Koc
Value:
1.9
Temp.:
25 °C
Type:
Koc
Value:
88

Any other information on results incl. tables

Table 1: Retention times in minutes of the reference items and the test items:

 

1st run

2nd run

3rd run

4th run

5th run

6th run

Sodium nitrate

1.177

1.177

 

 

 

 

Reference Items:

Acetanilide

3.058

3.069

3.060

3.071

3.060

3.059

Isoproturon

3.587

3.600

3.592

3.603

3.596

3.589

Linuron

4.465

4.483

4.479

4.489

4.486

4.470

Pyrazophos

5.698

5.729

5.730

5.737

5.747

5.707

Diclofop-methyl

6.666

6.707

6.705

6.717

6.736

6.678

2,4-DDT

10.252

10.360

10.343

10.385

10.429

10.293

LA 96

Test Item Peak

3.656

3.657

3.695

 

 

 

Table 2: Result of LA 96 analyses:

Number of analyses

Retention time [min]

k‘

Log k‘

Log Koc

Mean log Koc

Koc

Mean Koc

Test Item Peak

 

 

 

 

 

 

 

1

3.66

2.11

0.3235

1.9

 

85.158

 

2

3.66

2.11

0.32368

1.9

 

85.381

 

3

3.70

2.14

0.33028

2.0

1.9

94.94.209

88.2

Applicant's summary and conclusion

Conclusions:
In conclusion, the log of the adsorption coefficient (Koc) of LA 96 was estimated to be log Koc = 1.9 which is equal to Koc value of 88 using the HPLC method. This value indicates that LA 96 is of high mobility.