Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

4.1 Description of first aid measures

*General information

Personal protection for the First Aider.

Instantly remove any clothing soiled by the product.

Remove breathing apparatus only after soiled clothing has been completely removed.

In case of irregular breathing or respiratory arrest provide artificial respiration.

*After inhalation

Supply fresh air or oxygen; call for doctor.

In case of unconsciousness bring patient into stable side position for transport.

*After skin contact

Instantly wash with water and soap and rinse thoroughly.

Seek medical treatment.

*After eye contact

Rinse opened eye for several minutes under running water. Then consult doctor.

*After swallowing

Rinse out mouth and then drink plenty of water.

Do not induce vomiting; instantly call for medical help.

4.2 Most important symptoms and effects, both acute and delayed No further relevant information available.

*Information for doctor

Therapeutically measures: basic help, decontamination, symptomatic treatment.

4.3 Indication of any immediate medical attention and special treatment needed

No further relevant information available.

Fire-fighting measures

5.1 Extinguishing media

*Suitable extinguishing agents

CO2, extinguishing powder or water jet. Fight larger fire with foam.

*For safety reasons unsuitable extinguishing agents

Water with a full water jet.

5.2 Special hazards arising from the substance or mixture

*Can be released in case of fire

Carbon monoxide (CO)

Hydrocarbons

5.3 Advice for firefighters

*Protective equipment:

Wear self-contained breathing apparatus.

Do not inhale explosion gases or combustion gases.

*Additional information

Cool endangered containers with water spray jet.

Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.

Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Wear protective equipment. Keep unprotected persons away.

Use breathing protection against the effects of fumes / aerosol.

6.2 Environmental precautions:

Prevent material from reaching sewage system, holes and cellars.

Inform respective authorities in case product reaches water or sewage system.

6.3 Methods and material for containment and cleaning up:

Ensure adequate ventilation.

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders).

Send for recovery or disposal in suitable containers.

Dispose of contaminated material as waste according to item 13.

6.4 Reference to other sections

See Section 8 for information on personal protection equipment.

Handling and storage

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediates. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each Manufacturing site.

Written confirmation of application of Strictly Controlled Conditions has been received from every affected Distributor or Manufacturer / Downstream User of the Registrant’s intermediate.

7.1 Precautions for safe handling

Ensure good ventilation/exhaustion at the workplace.

Open and handle container with care.

Prevent formation of aerosols.

Precautions against electrostatic charging.

*Information about protection against explosions and fires:

Keep ignition sources away - Do not smoke.

Protect against electrostatic charges.

Keep breathing equipment ready.

7.2 Conditions for safe storage, including any incompatibilities

Storage

*Requirements to be met by storerooms and containers:

Storehouses and workplaces must be sufficiently ventilated.

Store in cool location.

Provide floor trough without outlet.

*Information about storage in one common storage facility:

Store away from oxidizing agents.

*Further information about storage conditions:

strictly controlled conditions

7.3 Specific end use(s)

No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3295
Shipping information
Proper shipping name and description:
3295 HYDROCARBONS, LIQUID, N.O.S., special provision 640D (BENZENE), ENVIRONMENTALLY HAZARDOUS
Chemical name:
-
Language:
English
Labels:
3
Special marking: Symbol (fish and tree)
Special provisions / remarks
Special provisions:
Excepted quantities (EQ): E2
Limited quantities (LQ): 1L
Tunnel restriction code: D/E
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediates. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each Manufacturing site.

Written confirmation of application of Strictly Controlled Conditions has been received from every affected Distributor or Manufacturer / Downstream User of the Registrant’s intermediate.

Additional information about design of technical systems: No further data; see item 7.

8.1 Control parameters

*Components with limit values that require monitoring at the workplace:

108-88-3 toluene

WEL Short-term value: 384 mg/m³, 100 ppm

Long-term value: 191 mg/m³, 50 ppm

Sk

1330-20-7 xylene, mixed isomers

WEL Short-term value: 441 mg/m³, 100 ppm

Long-term value: 220 mg/m³, 50 ppm

Sk; BMGV

71-43-2 benzene

WEL Long-term value: 1 ppm

Carc; Sk

8.2 Exposure controls

*Personal protective equipment

*General protective and hygienic measures

The usual precautionary measures should be adhered to general rules for handling chemicals.

Keep away from foodstuffs, beverages and food.

Take off immediately all contaminated clothing

Wash hands during breaks and at the end of the work.

Store protective clothing separately.

Avoid contact with the eyes and skin.

*Breathing equipment:

In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or longer exposure use

breathing apparatus that is independent of circulating air.

Short term filter device:

Filter A/P2.

*Protection of hands:

Only use chemical-protective gloves with CE-labelling of category III (EN 374).

*Material of gloves

The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies

from manufacturer to manufacturer.

Fluorocarbon rubber (Viton)

*Penetration time of glove material

The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

*Eye protection:

Tightly sealed safety glasses.

*Body protection:

Protective work clothing.

Stability and reactivity

10.1 Reactivity

10.2 Chemical stability

Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.

10.3 Possibility of hazardous reactions

Can form explosive mixtures in air if heated above flash point and/or when sprayed or atomised

10.4 Conditions to avoid

No further relevant information available.

10.5 Incompatible materials

No further relevant information available.

10.6 Hazardous decomposition products:

No dangerous decomposition products known

Disposal considerations

13.1 Waste treatment methods

*Recommendation

Remove according to local authority recommendations, e.g. convey to a suitable incinerator.

*European waste catalogue

The waste code classification is to be carried out according to the European Waste Catalogue (EWC) specifically for each

branch of industry and each type of process.

*Uncleaned packagings:

Recommendation: Disposal must be made according to official regulations.