Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
Jan 5, 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Principles of method if other than guideline:
Calculation based on KOWWIN v1.68, Estimation Programs Interface Suite™ for Microsoft® Windows v4.10. US EPA, United States Environmental Protection Agency, Washington, DC, USA.
GLP compliance:
no
Type of method:
other: QSAR
Partition coefficient type:
octanol-water
Analytical method:
other: QSAR calculation
Partition coefficient:
>= 17.49 - <= 32.14
Remarks on result:
other: QSAR result, therefore, temperature and pH are not available

For detailed information see attached Report.

Conclusions:
The log Pow was calculated (QSAR) with KOWWIN. Due to the fact that this substance is a long chain hydrocarbon which exceeds the applicability domain of KOWWIN the value for log Pow is reported with restrictions.
The applicability domain covers log Pow up to 10 (maximum) so these values should be given as log Pow > 10.
The concrete value is reported to show the high lipophilic nature of the substance.

Description of key information

log Pow > 10 (QSAR, KOWWIN v1.68)

Key value for chemical safety assessment

Additional information

The log Pow of the substance was estimated by QSAR calculation with KOWWIN (v1.68) for the single components.

As the calculated value exceeds the applicability domain of the model, the value is reported as log Pow > 10.