Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 12 March 2010 to 13 April 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test done following an OECD guideline according to GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
determination of fibre length and diameter distributions
Type of distribution:
counted distribution

Test material

Constituent 1
Reference substance name:
Tin, melting residues
EC Number:
283-659-9
EC Name:
Tin, melting residues
Cas Number:
84696-55-9
Molecular formula:
Not applicable
IUPAC Name:
Tin, melting residues
Details on test material:
- Name of test material (as cited in study report): MC_SMR_129 FN MELTING RES 1002
- Composition of test material, percentage of components: see point 1.2
- Purity test date: not applicable
- Lot/batch No.: 129
- Expiration date of the lot/batch: Not provided
- Stability under test conditions:
- Storage condition of test material: in darkness at room temperature

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 1.4 - <= 2 mm
Distribution:
1.1 %
No.:
#2
Size:
> 1 - <= 1.4 mm
Distribution:
29.8 %
No.:
#3
Size:
> 710 - <= 1 000 µm
Distribution:
59.7 %
No.:
#4
Size:
> 500 - <= 710 µm
Distribution:
6.8 %
No.:
#5
Size:
> 355 - <= 500 µm
Distribution:
0.8 %
No.:
#6
Size:
<= 355 µm
Distribution:
0 %

Applicant's summary and conclusion

Conclusions:
For the series of sieves between 1 and 4 mm, the majority of the particles (87.1%) was situated between 1 and 1.4 mm. The quantity of test item used for this series was 34.2% of the initial mass of test item used for the preliminary sieving.
For the series of sieves between 100 μm and 1 mm, the majority of the particles (86.8%) was situated between 710 μm and 1 mm. The quantity of test item used for this series was 65.6% of the initial mass of test item used for the preliminary sieving.