Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-10-20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
ASTM D 7094-04
Deviations:
no
Remarks:
ASTM D 7094-04 gives equal results as ASTM D 93
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky Martens
Key result
Flash point:
392 K
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point: 392 K (119 ºC)
Executive summary:

The flash point of the substance was determined by the closed cup method using an instrument-specific cup. The flash point was 392 K (119 °C). Thus, classification as flammable liquid is not warranted.

Description of key information

The flash point of Polyol TD is 392 K (119 °C) (Analytical Chemistry, Perstorp Holding AB, 2009). Thus, classification as flammable liquid is not warranted.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
119 °C

Additional information