Administrative data

First-aid measures

BASF safety data sheet, 27.05.2008

General advice:

Remove contaminated clothing.

If inhaled:

Keep patient calm, remove to fresh air.

On skin contact:

Wash thoroughly with soap and water.

On contact with eyes:

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

On ingestion:

Immediately rinse mouth and then drink plenty of water, do not induce vomiting, seek medical

attention.

Note to physician:

Treatment: Symptomatic treatment (decontamination, vital functions).

Fire-fighting measures

BASF safety data sheet, 27.05.2008

Suitable extinguishing media:

dry extinguishing media, carbon dioxide, foam

Unsuitable extinguishing media for safety reasons:

water

Specific hazards:

carbon dioxide, water

Special protective equipment:

Wear a self-contained breathing apparatus.

Further information:

Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.

Accidental release measures

BASF safety data sheet, 27.05.2008

Personal precautions:

Ensure adequate ventilation. Avoid contact with the skin, eyes and clothing.

Environmental precautions:

Do not empty into drains.

Methods for cleaning up or taking up:

For large amounts: Dike spillage. Pump off product.

For residues: Pick up with suitable absorbent material.

Dispose of absorbed material in accordance with regulations.

Handling and storage

BASF safety data sheet, 27.05.2008

Handling

Handle in accordance with good industrial hygiene and safety practice.

Protection against fire and explosion:

The relevant fire protection measures should be noted.

Storage

Further information on storage conditions: Keep container tightly closed and dry; store in a cool

place. Keep away from heat. Keep container in a well-ventilated place.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

BASF safety data sheet, 27.05.2008

Personal protective equipment

Respiratory protection:

Respiratory protection in case of vapour/aerosol release. Gas filter for gases/vapours of organic

compounds (boiling point >65 °C, e. g. EN 14387 Type A)

Hand protection:

Chemical resistant protective gloves (EN 374)

Suitable materials short-term contact and/or splashes (recommended: At least protective index 2,

corresponding > 30 minutes of permeation time according to EN 374)

butyl rubber (butyl) - 0.7 mm coating thickness

nitrile rubber (NBR) - 0.4 mm coating thickness

Supplementary note: The specifications are based on tests, literature data and information of glove

manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.

temperature) it must be considered, that the practical usage of a chemical-protective glove in

practice may be much shorter than the permeation time determined through testing.

Eye protection:

Safety glasses with side-shields (frame goggles) (e.g. EN 166)

General safety and hygiene measures:

Handle in accordance with good industrial hygiene and safety practice.

Stability and reactivity

BASF safety data sheet, 27.05.2008

Conditions to avoid:

Avoid heat.

Substances to avoid:

oxidizing agents

Hazardous reactions:

No hazardous reactions when stored and handled according to instructions.

Hazardous decomposition products:

No hazardous decomposition products if stored and handled as prescribed/indicated.

Disposal considerations

BASF safety data sheet, 27.05.2008

Observe national and local legal requirements.