Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 208-859-5 | CAS number: 544-10-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures:
Pay attention to self-protection.
Remove victims from hazardous area.
Immediately remove soiled or soaked clothing and remove it to a safe distance.
Keep victim warm, in a stabilized position and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.
Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move victims into fresh air.
With labored breathing: Provide with oxygen. Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.
Skin contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
If symptoms persist, consult a physician for treatment.
Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.
Ingestion:
Rinse out mouth.
Immediately give large quantities of water to drink.
Consult a physician immediately.
Most important symptoms and effects, both acute and delayed:
Indication of any immediate medical attention and special treatment needed:
This substance does not have any noteworthy noxious potential. Damage to health is thus not expected.
Fire-fighting measures
Suitable extinguishing media:
Water spray, foam, CO2, dry powder.
Unsuitable extinguishing media:
high volume water jet
Special hazards arising from the substance or mixture:
In case of fire cool endangered containers with water.
Hazardous fumes in fires, specific to the product:
hydrochloric acid
Under certain fire conditions, traces of other toxic products may occur.
Special protective equipment for fire-fighters:
Wear suitable protective clothing.
wear a self contained respiratory apparatus
Advice for firefighters:
Water used to extinguish fire should not enter drainage systems, soil, or stretches of water Ensure there are sufficient retaining facilities for water used to extinguish fire.
Contaminated fire-extinguishing water must be disposed of in accordance with the regulations issued by the appropriate local authorities.
Fire residues should be disposed of in accordance with the regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Ensure adequate ventilation.
Do not allow to enter drains (danger of explosion).
Keep away from sources of ignition - No smoking.
Wear personal protective equipment.
Environmental precautions:
Prevent product from entering drains.
Do not allow entrance in sewage water, soil or stretches of water.
Methods and material for containment and cleaning up:
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Handling and storage
Handling:
Precautions for safe handling:
Use permissible in closed systems only. Handle and transfer product in closed systems only (gas displacement device).
Ensure that apparatus and pipelines are free from leaks.
Do not ventilate into the open.
Suitable loading and unloading device required.
Provide good ventilation or extraction.
Observe the rules usually applicable when handling chemicals.
Wear personal protective equipment.
Advice on protection against fire and explosion:
Take precautionary measures against static charges, keep away from sources of ignition.
Storage:
Conditions for safe storage, including any incompatibilities:
Keep container tightly closed.
Keep in a well-ventilated place.
Keep in a cool place.
Unsuitable materials: light metals, iron
German storage class:
3 - Flammable liquids
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- FLAMMABLE LIQUID, N.O.S. (n-Hexyl chloride)
- Chemical name:
- n-Hexyl chloride
- Language:
- English
- Labels:
- 3
Special provisions / remarks
- Special provisions:
- ADR: Special provision 640E
RID: Special provision 640E - Remarks:
- Tunnel Restriction Code (ADR): (D/E)
orange warning plate: 30/1993
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- FLAMMABLE LIQUID, N.O.S. (n-Hexyl chloride)
- Chemical name:
- n-Hexyl chloride
- Language:
- English
- Labels:
- 3
Special provisions / remarks
- Remarks:
- ADNR: Special provision 640E
Marine transport (UN RTDG/IMDG)
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- FLAMMABLE LIQUID, N.O.S. (n-Hexyl chloride)
- Chemical name:
- n-Hexyl chloride
- Labels:
- 3
- Marine pollutant
Special provisions / remarks
- Remarks:
- UN-Placard: 1993
Marine pollutant
IMDG: IMDG Code segregation group 10 - Liquid halogenated hydrocarbons
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- Flammable liquid, n.o.s. (n-Hexyl chloride)
- Chemical name:
- n-Hexyl chloride
- Labels:
- 3
Special provisions / remarks
- Remarks:
- IATA_C: ERG-Code 3L
IATA_P: ERG-Code 3L
Additional transport information
Additional information
- Special provisions / remarks / other:
- Combination traffic : Labelling of containers / shipping units following main product run as per sea or air transport regulations.
Exposure controls / personal protection
Control parameters:
Engineering measures:
Refill and handle product only in closed system.
Leak detection recommended
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
Wastewater can be added to a biological wastewater treatment plant.
Dispose of waste gases in a suitable incineration plant.
All precautionary measures indicated have to be observed.
Exposure controls:
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH Ordinance.
Personal protective equipment:
Respiratory protection:
Accidental release measures:
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded:
use respiratory equipment with suitable filter or wear a self contained respiratory apparatus
Note time limit for wearing respiratory protective equipment.
Hand protection:
Accidental release measures:
Combustion preventative gloves
Glove material: Fluorinated rubber (Viton), Multiple-layer glove (4 h glove)
Material thickness: 0,5 mm
Break through time: > 480 min
Method: DIN EN 374
Eye protection:
Accidental release measures:
safety glasses with side-shields conforming to EN166
Skin and body protection:
Accidental release measures:
Wear protective clothing, apron.
Hygiene measures:
Do not inhale vapours / aerosols.
Avoid contact with skin and eyes.
Wash off immediately in the event of contact with the skin (rinsing agent: glycol polyethylene 400), rinse off afterwards with copious amounts of water.
No eating, drinking, smoking, or snuffing tobacco at work. Wash face and/or hands before break and end of work.
Take off clothing and shoes contaminated with product. Clean before reuse.
Protective measures:
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
All precautionary measures indicated have to be observed.
Risk assessment and risk monitoring of all work places required.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.
Stability and reactivity
Hazardous decomposition products: hydrogen chloride
Disposal considerations
Product:
Must, in conformance with local regulations, be subjected to special treatment, e.g. waste incineration plant suitable for materials causing emissions of harmful substances.
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Wastewater can be added to a biological wastewater treatment plant.
Uncleaned packaging:
Dispose of as special waste in compliance with local and national regulations.
Waste Key Number:
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the (as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.