Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Original reference not available
Principles of method if other than guideline:
no data
GLP compliance:
not specified
Flash point:
95 °C

migrated data set

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Flash point:
113 °C

atmospheric pressure not reported.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Flash point:
112.7 °C

atmospheric pressure not reported.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Type of method:
open cup
Flash point:
113 °C
atmospheric pressure not reported
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Flash point:
91 °C

atmospheric pressure not reported.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Flash point:
91 °C
atmospheric pressure not reported
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
91 °C
Atm. press.:
101.3 kPa
Conclusions:
non flammable liquid

Description of key information

The reported flash points range from 91°C to 113°C. As worst case a flash point of 91°C is assumed for that substance.

Key value for chemical safety assessment

Additional information