Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to guideline DIN EN ISO 2719

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
raw Glycerol phase (KFSBiodiesel)
IUPAC Name:
raw Glycerol phase (KFSBiodiesel)
Details on test material:
ID number 176817

Results and discussion

Flash point
Flash point:
32 °C
Remarks on result:
other: It can be assumed that the study was performed under atmospheric pressure.

Applicant's summary and conclusion

Conclusions:
In a study according to the guideline DIN EN ISO 2719, the flash point of the registered substance was determined to be 32°C.
Executive summary: