Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 234-522-7 | CAS number: 12007-92-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 15/06/2010 - 16/06/2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- other: BS ISO 13320-1:999
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- other: CIPAC MT 187
- Deviations:
- not specified
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
- Deviations:
- not specified
- GLP compliance:
- yes
- Type of method:
- determination of fibre length and diameter distributions
- Type of distribution:
- volumetric distribution
- Percentile:
- D90
- Mean:
- 424.293 µm
- St. dev.:
- 5.65
- Percentile:
- D10
- Mean:
- 52.462 µm
- St. dev.:
- 0.25
- Percentile:
- D50
- Mean:
- 170.849 µm
- St. dev.:
- 1.87
- Conclusions:
- The particle size distribution of sodium pentaborate granular was assessed according to BS ISO 13320-1:1999 and CIPAC MT 187. The coefficient of variation for d50 was less than 3 %; d10 and d90 were less than 5 %. Thus repeatability of the characteristic particles in the size distribution were within the acceptable limits as per the BS ISO 13320-1 test standard. The median (d50) was 170.849 μm.
- Executive summary:
The particle size distribution study was performed according to BS ISO 13320-1: 1999, CIPAC MT 187 and OECD guideline 110 under GLP compliance. Determination of fibre length and diameter distributions method was used. The coefficient of variation for d50 was less than 3 %; d10 and d90 were less than 5 %. The median (d50) was 170.849 μm.
Reference
Full test results:
|
Run 1 |
Run 2 |
Run 3 |
Run 4 |
Run 5 |
** Average |
Volume weighted mean |
206.472 |
208.131 |
210.343 |
218.379 |
211.471 |
210.959 |
Median (d.50) |
171.086 |
171.984 |
173.583 |
168.267 |
169.448 |
170.849 |
Mode (μm) |
184.988 |
184.414 |
187.289 |
174.668 |
177.405 |
181.244 |
*MMAD |
222.411 |
223.580 |
225.658 |
218.747 |
220.282 |
222.103 |
10 % of material was < |
52.358 |
52.648 |
52.859 |
52.287 |
52.168 |
52.462 |
50 % of material was < |
171.086 |
171.984 |
137.583 |
168.267 |
169.448 |
170.849 |
90 % of material was < |
416.444 |
420.596 |
425.418 |
432.336 |
428.670 |
424.293 |
All results are in μm.
* Mass Mean Aerodynamic Diameter
** Average result was calculated from the entirety of the data captured in each run and is not a simple arithmetic mean.
1.61 % by volume of sample was seen to be < 10.00 μm.
Standard deviation results:
Run No. |
1 |
2 |
3 |
4 |
5 |
STDVP |
% STDV |
d10 |
52.358 |
52.648 |
52.859 |
52.287 |
52.168 |
0.25 |
0.48 |
d50 |
171.086 |
171.984 |
173.583 |
168.267 |
169.448 |
1.87 |
1.09 |
d90 |
416.444 |
420.596 |
425.418 |
432.336 |
428.670 |
5.65 |
1.33 |
d15.78 |
72.630 |
73.120 |
73.520 |
72.770 |
72.530 |
0.36 |
0.50 |
GSD* |
2.356 |
2.352 |
2.361 |
2.312 |
2.336 |
0.02 |
0.75 |
MMAD |
222.411 |
223.580 |
225.658 |
218.747 |
220.282 |
2.43 |
1.09 |
* GSD = Geometric standard deviation
Coefficient of variation for d50 is less than 3 %; d10 and d90 are less than 5 %. Thus repeatability of the characteristic particles in the size distribution are within the acceptable limits as per the BS ISO 13320 -1 test standard.
Description of key information
The particle size distribution study was performed according to BS ISO 13320-1: 1999, CIPAC MT 187 and OECD guideline 110 under GLP compliance. Determination of fibre length and diameter distributions method was used. The coefficient of variation for d50 was less than 3 %; d10 and d90 were less than 5 %. The median (d50) was 170.849 μm.
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.