EC number: 234-426-5 | CAS number: 12003-38-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
After inhalation: fresh air.
After skin contact: wash off with plenty of water. Remove contaminated clothing.
After eye contact: rinse out with plenty of water.
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Most important symptoms and effects, both acute and delayed:
We have no description of any toxic symptoms.
Indication of any immediate medical attention and special treatment needed:
No information available.
Fire-fighting measures
Suitable extinguishing media: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media: For this substance/mixture no limitations of extinguishing agents are given.
Special hazards arising from the substance or mixture:
Not combustible.
Ambient fire may liberate hazardous vapours.
Advice for firefighters:
Special protective equipment for firefighters: In the event of fire, wear self-contained breathing apparatus.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Advice for emergency responders: Protective equipment.
Environmental precautions: No special precautionary measures necessary.
Methods and materials for containment and cleaning up:
Observe possible material restrictions.
Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.
Handling and storage
Precautions for safe handling:
Observe label precautions.
Conditions for safe storage, including any incompatibilities:
Tightly closed. Dry.
Storage temperature: no restrictions.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Exposure controls:
Engineering measures
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.
Individual protection measures
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.
Hygiene measures
Change contaminated clothing. Wash hands after working with substance.
Eye/face protection
Safety glasses
Hand protection
not required
Respiratory protection
required when dusts are generated.
Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be according to Regulation (EC) No. 1907/2006 properly documented.
Stability and reactivity
Chemical stability
The product is chemically stable under standard ambient conditions (room temperature) .
Possibility of hazardous reactions
no information available
Conditions to avoid
not known to date
Incompatible materials
no information available
Hazardous decomposition products
no information available
Disposal considerations
Waste treatment methods:
Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.