Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable
Guideline:
other: measured
Principles of method if other than guideline:
Method: vapour pressure curve
GLP compliance:
no
Type of method:
dynamic method
Temp.:
30.6 °C
Vapour pressure:
2.01 hPa
Temp.:
61.9 °C
Vapour pressure:
15.5 hPa
Temp.:
89.2 °C
Vapour pressure:
65.1 hPa
Temp.:
130.8 °C
Vapour pressure:
386.5 hPa
Temp.:
159.3 °C
Vapour pressure:
1 013 hPa

Temperature, ° C / pressure, hPa:
30.6/2.01;

46.6/5.93;

61.9/15.5;

69.9/24.3;

89.2/65.1;
108.9/160.1;

130.8/386.5;

151.8/798.5;

159.3/1013

Conclusions:
VP = 2.01 hPa at 30.6°C
Executive summary:

Vapour pressure was determined experimentally by dynamic method. Measurements were performed at 9 temperature levels and a vapour pressure curve was plotted.Temperature, ° C / pressure, hPa: 30.6/2.01; 46.6/5.93; 61.9/15.5; 69.9/24.3; 89.2/65.1; 108.9/160.1; 130.8/386.5; 151.8/798.5; 159.3/1013.

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination
GLP compliance:
not specified
Type of method:
other: experimental determination
Temp.:
20 °C
Vapour pressure:
1 mBar
Temp.:
64 °C
Vapour pressure:
16 mBar
Conclusions:
VP = 1 mbar at 20°C,
VP = 16 mbar at 64°C
Executive summary:

VP = 1 mbar at 20°C,

VP = 16 mbar at 64°C

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination
GLP compliance:
not specified
Type of method:
other: experimental determination
Temp.:
25 °C
Vapour pressure:
1.08 mm Hg
Conclusions:
VP = 1.08 mm Hg at 25°C
Executive summary:

VP = 1.08 mm Hg at 25°C

Description of key information

Vapour pressure: 2.01 hPa at 30.6°C (measured)

Key value for chemical safety assessment

Vapour pressure:
2.01 hPa
at the temperature of:
30.6 °C

Additional information

The vapour pressure was experimentally determined by a dynamic method (BASF, 1972). Nine different temperature levels were used in this test (~ 30°C - ~ 160 °C).