Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Additional physico-chemical information

Currently viewing:

Administrative data

Endpoint:
other: Minimum Ignition Energy
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was well documented and meets generally accepted scientific principles, but was not conducted in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Principles of method if other than guideline:
Experimental measurement (data is taken from a reliable handbook, information about the methodology is not available)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Trichloro(methyl)silane
EC Number:
200-902-6
EC Name:
Trichloro(methyl)silane
Cas Number:
75-79-6
Molecular formula:
CH3Cl3Si
IUPAC Name:
trichloro(methyl)silane

Results and discussion

Results:
Minimum Ignition Energy Determination

Any other information on results incl. tables

MIE = 1.0-2.0 mJ
Sample tested at 20 deg C

Spark Energy (mJ)

Voltage (Kv)

Capacitance (PF)

Observations

20

10.15

38.8

Yes/ Small flame High pressure

 1.0

 7.18

 38.8

 No ignition

 1.0

 7.18

 38.0

  No ignition

1.0

6.63

45.5

 No ignition




--------------
MIE = 5.0 - 10 mJ
Comments: Sample tested at 40 deg C

Spark Energy (mJ)

Voltage (Kv)

Capacitance (PF)

Observations

2.0

9.84

41.3

No ignition

 1.0

6.95

41.3

No ignition

0.5

4.92

41.3

No ignition

3.0

12.05

41.3

No ignition

25

10.5

300

Yes/Small flame, Medium pressure

10

9.2

100

No ignition

10

9.2

100

Yes/Small flame, High pressure

5

16.55

36.5

No ignition

5

16.55

36.5

No ignition


-----------------
MIE = 2.0- 3.0 mJ
Comments: Sample tested at 15 deg C

Spark Energy (mJ)

Voltage (Kv)

Capacitance (PF)

Observations

10

10.5

100

Yes/Small flame, High pressure, lots smoke

5

14.6

47.1

Yes/Small flame, High pressure, lots smoke

3

11.29

47.1

Yes/Small flame, High pressure, lots smoke

2

9.26

46.6

No ignition

2

9.26

46.6

No ignition

Applicant's summary and conclusion

Conclusions:
The minimum ignition energy was determined in a reliable study conducted according to generally accepted scientific principles.