Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1
GLP compliance:
no
Type of method:
other: not specified
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
93.754 µm
St. dev.:
1
Remarks on result:
other: no std dev info available
Percentile:
D50
Mean:
583.221 µm
St. dev.:
1
Remarks on result:
other: no std dev info available
Percentile:
D90
Mean:
1 359.628 µm
St. dev.:
1
Remarks on result:
other: no std dev info available

No further information.

Conclusions:
The particle size distribution of the four preparations was measured to be D10 = 93.574 µm, D50 = 583.221 µm and D90 = 1359.628 µm.
Executive summary:

The particle size distribution of four calcium fluoride preparations were measured.

The mean distribution was D10 = 93.574 µm, D50 = 583.221 µm and D90 = 1359.628 µm.

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Remarks:
Modern study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
GLP compliance:
no
Type of method:
other: not specified
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
1.83 µm
St. dev.:
1
Remarks on result:
other: std dev info not available
Percentile:
D50
Mean:
6.16 µm
St. dev.:
1
Remarks on result:
other: no std dev info available
Percentile:
D90
Mean:
16.67 µm
St. dev.:
1
Remarks on result:
other: no std dev info available

No further information.

Conclusions:
The particle size distribution was measured to be D10 = 1.83 µm, D50 = 6.16 µm and D90 = 16.67 µm.
Executive summary:

The particle size distribution was measured for a sample of calcium fluoride. The results were as follows: D10 = 1.83 µm, D50 = 6.16 µm and D90 = 16.67 µm.

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Modern study performed to current guidelines.
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ISO 565:1990
GLP compliance:
no
Type of method:
sieving
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
4.43 µm
St. dev.:
1
Remarks on result:
other: no std dev info available
Percentile:
D50
Mean:
15.096 µm
St. dev.:
1
Remarks on result:
other: no std dev info available
Percentile:
D90
Mean:
45.848 µm
St. dev.:
1
Remarks on result:
other: no std dev info available

Size (µm)

Volume in %

Size (µm)

Volume in %

0.500

-

45.000

12.52

1.000

0.38

63.000

6.25

2.000

1.25

75.000

1.75

5.000

10.98

105.000

1.54

10.000

21.41

150.000

0.52

20.000

27.36

250.000

0.39

30.000

15.69

>250.000

0

Conclusions:
The median diameter was determined to be 15.096 µm.
Executive summary:

The particle size distribution was determined for a sample of calcium fluoride. The D10, D50 and D90 were determined to be 4.43, 15.096, 45.848 µm respectively.

Description of key information

Data are provided for a number of sources of calcium fluoride. The median diameter (D50) was found to be in the range of 6.16 - 583.22 µm.

The 3 key studies for this endpoint are the data provided by CILAS, BASF and Derivados Del Fluor. The other 3 results (provided by Alufluor, CILAS and Prayon) are used as supporting studies.

Additional information