Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vivo
Adequacy of study:
other information

Data source

Reference
Title:
No information
Author:
BASF AG, department of toxicology, unpublished data,|(91/467), 22. July 92

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
oxane-4-carbaldehyde
Cas Number:
50675-18-8
Molecular formula:
C6 H10 O2
IUPAC Name:
oxane-4-carbaldehyde
Details on test material:
IUCLID4 Test substance: as prescribed by 1.1 - 1.4

Test animals / tissue source

Species:
rabbit

Test system

Amount / concentration applied:
Amount applied: 0.1 ml
Number of animals or in vitro replicates:
3

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
irritating
Remarks:
Migrated information
Conclusions:
Classification: irritating