Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jun 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 279.8 - <= 305.7 °C
Atm. press.:
100.9 kPa
Conclusions:
The boiling point was between 279.8 and 305.7 ˚C at 100.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 279.8 and 305.7 ˚C at 100.9 kPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 240.4 - <= 313.3 °C
Atm. press.:
102.9 kPa
Conclusions:
The boiling point was observed between 240.4 and 313.3 ˚C at 102.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 240.4 and 313.3 ˚C at 102.9 kPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: ASTM E537-07
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
>= 239.4 - <= 314.1 °C
Atm. press.:
102.9 kPa
Conclusions:
The boiling point was observed between 239.4 and 314.1 ˚C at 102.9 kPa.
Executive summary:

To determine the boiling temperature of the test substance a study was performed according to ASTM E537-07 and in compliance with GLP. This DSC study showed a boiling point between 239.4 and 314.4 ˚C at 102.9 kPa.

Description of key information

The boiling point of the test subtstance was conducted according to the ASTM E537-07 method by using DSC and was found to be 239.9 - 314.1 ˚C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
279 °C

Additional information

279 °C is the median range of the experimental values.