Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 March 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
54.89 µm
Remarks on result:
other: No information on standard deviation

d(0.1): 8.163 µm

d(0.5): 54.890 µm

d(0.9): 156.342 µm

- Specific surface area: 0.407 m2/g

- Surface weighted mean D[3,2]: 12.285 µm

- Volume weighted mean D[4,3]: 70.812 µm

Conclusions:
Under the conditions of this study the D50 was determined to be 54.890 µm.
Executive summary:

The particle size distribution of the test material was investigated using methodology broadly equivalent to that of the standardised guideline ISO 13320.

The particle size of the sample was measured by laser diffraction.

Under the conditions of this study the D50 was determined to be 54.890 µm.

Description of key information

Under the conditions of this study the D50 was determined to be 54.890 µm.

Additional information

The particle size distribution of the test material was investigated using methodology broadly equivalent to that of the standardised guideline ISO 13320. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

The particle size of the sample was measured by laser diffraction.

Under the conditions of this study the D50 was determined to be 54.890 µm.