Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28-02-2018 – 28-02-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The flash point determination of Test item was done by closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : Disperse Yellow 201
- IUPAC name : (4-{[2-(4-cyclohexylphenoxy)ethyl](ethyl)amino}-2-methylbenzylidene)malononitrile / Solvent Yellow 179
- Molecular formula): C27H31N3O
- Molecular weight :413.562 g/mol
- Smiles notation : N#C\C(C#N)=C/c1c(cc(N(CCOc2ccc(cc2)C2CCCCC2)CC)cc1)C
- InChl: 1S/C27H31N3O/c1-3-30(26-12-9-25(21(2)17-26)18-22(19-28)20-29)15-16-31-27-13-10-24(11-14-27)23-7-5-4-6-8-23/h9-14,17-18,23H,3-8,15-16H2,1-2H3
- Substance type:Organic
- Physical state:Solid
Key result
Flash point:
224.3 °C
Atm. press.:
977.4 hPa
Remarks on result:
other: no other details available

Method Details

 

Observations

Remarks if,

any

Method

Closed cup method

 

 

Principle of Flash point

test

The flash point of a flammable

liquid is the lowest temperature at which there will be enough

flammable vapor to ignite when an ignition source is applied.

 

Type of method

·        

 

Flash point apparatus

·        

·        

Pensky-Martens flash point apparatus

Quantity of chemical

used

g/ml

5.000g

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

977.4 hPa

meanFlash point

(RESULT)

°C

224.3°C

Interpretation of results:
other: non flammable
Conclusions:
The mean flash point of test chemical was 224.3°C at pressure 977.4 hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 224.3°C at pressure 977.4 hPa.

Description of key information

The mean flash point of test chemical was 224.3°C at pressure 977.4 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
224.3 °C

Additional information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 224.3°C at pressure 977.4 hPa.