Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
not determinable

Findings:

Safety Pre-Test:

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item FAT 36152/N should be considered as not highly flammable.
Executive summary:

A key study was performed to determine the flammability of FAT 36152/N according to EU Method A.10 (Flammability (Solids).


 


Safety Pre-Test:


A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.


 


Preliminary screening test:


The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. In the main test, no ignition was observed throughout the course of the test. Hence, the test item FAT 36152/N should be considered as not highly flammable.

Description of key information

The test item FAT 36152/N should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

A key study was performed to determine the flammability of FAT 36152/N according to EU Method A.10 (Flammability (Solids).


 


Safety Pre-Test:


A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.


 


Preliminary screening test:


The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. In the main test, no ignition was observed throughout the course of the test. Hence, the test item FAT 36152/N should be considered as not highly flammable.

Justification for classification or non-classification

FAT 36152/N was considered as not highly flammable, hence no classification is required as per the criteria of Regulation (EC) No. 1272/2008 (CLP).