Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6-26 February 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Data have been generated according to current internationally recognised study guidelines and in accordance with GLP.
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Details on study design: HPLC method:
Stationary Phase (HPLC Column): ACE 5 CN 150 × 4.6 mm, HPLC Column, No.: A47728 Merck-Hitachi LaChrom HPLC system: D-7000 Interface, No.: 1126-175 L-7100 HPLC pump, No.: 1388-056L-7200 Autosampler, No.: 1380-033 L-7400 UV Detector, No.: 1374-025 L-7360 Column Oven, No: 00118060 L-7614 Degasser, No.: 144116A0094 Ultrasonic bath: Elmasonic S300H, ELMA, No.: 010890105 Balances: BP221S Sartorius, No.: 11809117, Sartorius L220P, No.: 38100037 pH meter: Mettler Toledo, SevenEasy S20, No.: 1231025119 Water purification system: MILLIPORE, DIRECT Q8 UV, F3SA78247A Spectrophotometer: Hitachi U-2910, No.: 2221-004HPLC Conditions: Detector: UV at 254 nm Mobil Phase: 10 mM NaH2PO4 buffer solution (pH=6.0)/Acetonitrile=8/2 Flow: 1 ml/min. Injection volume: 20 μl Temperature: 25 °CDetermination of the retention times: Three series of the above reference solutions and the test item solution were measured alternately, with two replicate injections. For the determination of t0 (t0 = retention time of the unretarded component) sodium nitrate solution was injected. The retention times were determined.
Type:
log Koc
Value:
<= 1.25
Temp.:
25 °C
Type:
Koc
Value:
<= 17.78
Temp.:
25 °C

Due to the fact that BK-659 eluted before t0, the log Koc and Koc of BK-659 is lower than log Koc and Koc of the first reference substance (Acetanilide)

Validity criteria fulfilled:
yes
Conclusions:
The log Koc is <1.25
Executive summary:

The adsorption coefficient was measured by the HPLC method in accordance with the OECD 121 test guideline in compliance with GLP. The log Koc is <1.25.

Description of key information

The adsorption coefficient was measured by the HPLC method in accordance with the OECD 121 test guideline in compliance with GLP. The log Koc is <1.25.

Key value for chemical safety assessment

Koc at 20 °C:
17.78

Additional information

[LogKoc: 1.25]