Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study (ISO 11357); basic data given.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 11357
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Reference substance name:
Montan waxes, type WE 40
IUPAC Name:
Montan waxes, type WE 40
Details on test material:
Product Name Licolub WE 40 P
Purity: app. 100%

Results and discussion

Boiling point
Key result
Decomposition:
yes
Decomp. temp.:
>= 201.6 °C

Any other information on results incl. tables

A boiling point is not detectable, because of decomposition starting at 201.6 °C.

Applicant's summary and conclusion

Conclusions:
The test substance decomposes instead of boiling at 201.6 °C.
Executive summary:

The boiling point of the test substance was investigated by a Differential Scanning Calorimetry (DSC) measurement according to ISO 11357. The test substance decomposes (starting from 201.6 °C) instead of boiling.