Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.09.-23.09.2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
Reactive Orange 5 does not self-ignite in the temperature range tested (25 - 400 °C).
Executive summary:

The relative self-ignition temperature for solids of test substance, Reactive Orange 5, was determined.

The procedure was performed according to the Method A.16. Relative self-ignition temperature for solids,Council Regulation (EC) No.440/2008, Published in O.J. L 142, 2008

Reactive Orange 5 does not self-ignite in the temperature range tested (25 - 400 °C).

Description of key information

The relative self-ignition temperature for solids of test substance, Reactive Orange 5,was determined.

The procedure was performed according to the Method A.16. Relative self-ignition temperature for solids.

Only one study is available.

GLP study.

Klimish score 1.

Key value for chemical safety assessment

Additional information

Reactive Orange 5 does not self-ignite in the temperature range tested (25 - 400 °C).