Registration Dossier

Administrative data

First-aid measures

GENERAL INFORMATION
- Immediately remove any clothing soiled by the product
- Take affected persons out of the danger area and lay down

AFTER INHALATION
- Supply fresh air; consult doctor in case of complaints
- In case of unconsciousness place patient stably in side position for transportation

AFTER SKIN CONTACT
- Immediately rinse with water

AFTER EYE CONTACT
- Rinse opened eye for several minutes under running water then consult a doctor

AFTER SWALLOWING
- Do not induce vomiting; call for medical help immediately

Fire-fighting measures

SUITABLE EXTINGUISHING AGENTS
- Carbon dioxide, extinguishing powder or water spray
- Fight larger fires with water spray or alcohol resistant foam

EXTINGUISHING AGENTS UNSUITABLE FOR SAFETY REASONS
- Water with full jet

SPECIAL HAZARDS CAUSED BY THE MATERIAL, ITS PRODUCTS OF COMBUSTION OR RESULTING GASES
- Formation of toxic gases is possible during heating or in case of fire

PROTECTIVE EQUIPMENT
- Mount respiratory protective device

ADDITIONAL INFORMATION
- Dispose of fire debris and contaminated fire fighting water in accordance with official regulations

Accidental release measures

PERSON-RELATED SAFETY PRECAUTIONS
- Wear protective equipment
- Keep unprotected persons away

MEASURES FOR ENVIRONMENTAL PROTECTION
- Dilute with plenty of water
- Do not allow to enter sewers/surface or ground water

MEASURES FOR CLEANING/COLLECTING
- Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
- Use neutralising agent
- Dispose of contaminated material as waste
- Ensure adequate ventilation

Handling and storage

HANDLING

INFORMATION FOR SAFE HANDLING
- Open and handle receptacle with care
- When diluting, always stir the product into standing water, not water to product

INFORMATION ABOUT PROTECTION AGAINST EXPLOSIONS AND FIRES
- Protect from heat

STORAGE

INFORMATION ABOUT STORAGE IN ONE COMMON STORAGE FACILITY
- Do not store together with alkalis (caustic solutions)

FURTHER INFORMATION ABOUT STORAGE
- Protect from heat and direct sunlight
- Keep receptacle tightly sealed

MAXIMUM STORAGE TEMPERATURE
- Do not store above 25 °C

MINIMUM STORGE TEMPERATURE
- Do not store below 5 °C

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3098
Shipping information
Proper shipping name and description:
OXIDISING LIQUID, CORROSIVE, N.O.S.
Chemical name:
SULPHURIC ACID, HYDROGEN PEROXIDE, AQUEOUS SOLUTION
Language:
English
Labels:
5.1 + 8
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3098
Shipping information
Proper shipping name and description:
OXIDISING LIQUID, CORROSIVE, N.O.S.
Chemical name:
SULPHURIC ACID, HYDROGEN PEROXIDE, AQUEOUS SOLUTION
Labels:
5.1 + 8
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3098
Shipping information
Proper shipping name and description:
OXIDISING LIQUID, CORROSIVE, N.O.S.
Chemical name:
SULPHURIC ACID, HYDROGEN PEROXIDE, AQUEOUS SOLUTION
Labels:
5.1 + 8
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

COMPONENTS WITH LIMIT VALUES THAT REQUIRE MONITORING IN THE WORKPLACE

7722-84-1 hydrogen peroxide solution (2.5-10 %)
OES short-term value 2.8 mg/cubic metre, 2 ppm
OES long-term value 1.4 mg/cubic metre, 1 ppm

7664-93-9 sulphuric acid (90-100 %)
OES long-term value 1 mg/cubic metre

GENERAL PROTECTIVE AND HYGIENIC MEASURES
- Keep away from foodstuffs, beverages and feed
- Immediately remove all soiled and contaminated clothing
- Wash hands before breaks and at the end of work
- Avoid contact with the eyes and skin

BREATHING EQUIPMENT
- Use suitable respiratory protective device in case of insufficient ventilation

PROTECTION OF HANDS
- Acid resistant gloves where the the glove material is impermeable and resistant to the product / the substance / the preparation
- Due to missing tests, no recommendation to the glove material can be given for the product / the substance / the preparation / the chemical mixture
- Select glove material after consideration of penetration times, rates of diffusion and degradation

GLOVE MATERIAL
- Selection of suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a multi-constituent substance, the resistance of the glove material cannot be calculated in advance and therefore has to be checked prior to the application.

PENETRATION OF GLOVE MATERIAL
- The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

EYE PROTECTION
- Safety glasses

BODY PROTECTION
- Protective work clothing

Stability and reactivity

THERMAL DECOMPOSITION / CONSIDERATIONS TO BE AVOIDED
- No decomposition if used according to specifications

DANGEROUS REACTIONS
- Reacts with alkalis (lyes)
- Heating occurs when water is added

DANGEROUS PRODUCTS OF DECOMPOSITION
- Poisonous gases / vapours

Disposal considerations

PRODUCT
- Must not be disposed of together with household garbage
- Do not allow product to reach sewage system

UNCLEANED PACKAGING
- Disposal must take place according to official regulations

CLEANSING AGENT
- Water, if necessary with cleansing agents