Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
4-benzyloxyaniline hydrochloride
EC Number:
257-170-6
EC Name:
4-benzyloxyaniline hydrochloride
Cas Number:
51388-20-6
Molecular formula:
C13H13NO.ClH
IUPAC Name:
4-benzyloxyaniline hydrochloride
Test material form:
solid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
About 25 mg of the test item was spread evenly over the surface of the tissue and wetted with 25 μL deionised water.
For the positive and negative control tissues a volume of 50 μL was applied to each tissue.
Duration of treatment / exposure:
3 minutes and 1 hour.
Number of replicates:
Independent duplicate tissues were exposed to the test item, the negative control or the positive control.

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 minutes treatment
Value:
89.7
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1 hour treatment
Value:
68.3
Negative controls validity:
valid
Positive controls validity:
valid

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In conclusion, it can be stated that in this study and under the reported experimental conditions, the test item BOA.HCl was non corrosive to skin according to UN GHS / EU CLP Cat.1 / DSD (67/548/EEC).