Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction products of diphenyl ether and 9-methylene nonadecane
EC Number:
943-303-1
Molecular formula:
Variable, substance is a UVCB
IUPAC Name:
Reaction products of diphenyl ether and 9-methylene nonadecane
Test material form:
liquid

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficientopen allclose all
Type:
log Pow
Partition coefficient:
> 7.2
Temp.:
35 °C
pH:
7
Remarks on result:
other:
Remarks:
Temperature relates to column temperature
Type:
Pow
Partition coefficient:
> 16 000 000
Temp.:
35 °C
pH:
7
Remarks on result:
other:
Remarks:
Temperature relates to column temperature

Any other information on results incl. tables

In the chromatogram of the test item solution, no peak was observed. Under the same analytical conditions, the retention time of benzo[ghi]perylene (log Pow = 7.2)

was 16.815 and 15.964 minutes. When the test item was injected under the same analytical conditions with no column there was a response observed. Hence, it was concluded that the log Pow of test item

was > 7.2 (Pow > 1.6 x 10^7).

Applicant's summary and conclusion

Conclusions:
The HPLC method was applied for the determination of the partition coefficient (Pow) of the test substance.

The Pow and log Pow value of the test item at neutral pH was > 7.2 (Pow > 1.6 x 10^7).