Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 0011440677

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature
Key result
Flash point:
174 °C
Atm. press.:
1 013.25 hPa

Initial test: 176.0 °C

1st Run: 175.2 °C*

2nd Run: 173.2°C*

* Corrected flash point

Interpretation of results:
GHS criteria not met

Description of key information

174 °C at 1013.25 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
174 °C

Additional information

A study was conducted according ISO 2719 to determine the flash point of the test item using a Pensky-Martens apparatus. The flash point of the test item was determined to be 174 °C at 1013.25 hPa (BASF SE SIK 15/2193).