Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 June 2016 - 29 November 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6
Version / remarks:
United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6: Recommendations on the Transport of
Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to
Class 2, Class 3, Class 4, Division 5.1, Class 8 and Class 9, Paragraph 32.4.1: “Non-Viscous
Flammable Liquids”, 2009.
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM International, ASTM D7094
Version / remarks:
ASTM International, ASTM D7094: “Standard Test Method for Flash Point by Modified
Continuously Closed Cup (MCCCFP) Tester”, 2012.
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash tester

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(6-fluoro-3,4-dihydro-2H-1-benzopyran-2-yl)ethan-1-one
Cas Number:
620176-90-1
Molecular formula:
C11H11FO2
IUPAC Name:
1-(6-fluoro-3,4-dihydro-2H-1-benzopyran-2-yl)ethan-1-one
Test material form:
liquid
Details on test material:
- Name of test material (as cited in study reports): JNJ-7928531-AAA (T001481)
- Physical state: liquid
- Appearance: Colourless, light yellow to brown liquid
Specific details on test material used for the study:
- Batch n°: M16AB0419
- Expiration date: 23 September 2016
- Purity: 102.5% (based on GC assay)
- Storage condition of test material: at room temperature

Results and discussion

Flash point
Key result
Flash point:
132 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

-Preliminary test

The estimated flash-point of the test item was 134.5°C.

-Main study

The difference between the results obtained with the two tests was ≤ 6°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained.

Test   Flash-point [°C]  Lowest flash-point [°C]
 132  132   
2  132

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the closed cup method which was applied for the determination of the flash-point of JNJ-7928531-AAA (T001481) it is concluded that the flash-point of the test item was 132°C.