Registration Dossier

Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-06-11 to 2015-07-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: no stock solution could be prepared due to insufficient water solubility. 1L test bottle were filled with 200 mL of the test item mixtures in Milli-RO water with initial loading rate of 2.5 times the final loading rate. These mixtures were stirred in closed dark brown bottles for ~24h. 16 mL synthetic medium made up to 50 mL with Milli-RO water and 250 mL sludge were added resulting in the required loading rate (3.2, 10, 32, 100, 320 and 1000 mg/L). Optimal contact was ensured applying continuous aeration and stirring.
- Controls: blank controls: test medium without test item and treated in the same way as the test item solutions.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Laboratory culture: predominantly domestic sewage treatment plant, "Waterschap Aa en Maas", 's-Hertogenbosch, The Netherlands.
- Preparation of inoculum for exposure: coarsely sieved (1 mm) and allowed to settle. The supernatant was removed and ISO-medium was added. A small amount of the sludge was weighed and dried overnight at ~105°C to determine the amount of suspended solids
- Pretreatment: The batch of sludge was used one day after collection; therefore 50 mL of synthetic medium was added per L of activated sludge at the end of the collection day. The sludge was kept aerated at test temperature until use.
- Initial biomass concentration: 3.0 g/L of sludge
- The pH was 7.8 on the day of testing.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Hardness:
not applicable
Test temperature:
19.7-21.7°C
pH:
Before addition of sludge: 7.2-7.6.
After the 3-h exposure period: 7.7-8.3
Dissolved oxygen:
The aeration was adjusted in such a way that the dissolved oxygen concentration at the start was above 60-70% saturation (60% of air saturation is > 5 mg/L at 20°C) and to maintain the sludge flocs in suspension.
Salinity:
not applicable
Nominal and measured concentrations:
Nominal concentrations:
Combined limit/range-finding test: 10, 100 and 1000 mg/L
Final test: Control, 3.2, 10, 32, 100, 320, 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: All glass open bottles/vessels
- Aeration: The aeration was adjusted in such a way that the dissolved oxygen concentration at the start was above 60-70% saturation (60% of air saturation is > 5 mg/L at 20°C) and to maintain the sludge flocs in suspension.
- Number of replicates: 5
- Number of control replicates: 6
- Biomass loading rate: initial loading ca. 3.0 g dw/L

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: adjusted ISO medium, formulated using RO-water (tap water purified by reverse osmosis) GEON Waterbehandeling, Berkel-Enschot, The Netherlands) with the following composition:
CaCl2.2H2O 211.5 mg/l
MgSO4.7H2O 88.8 mg/l
NaHCO3 46.7 mg/l
KCl 4.2 mg/l

EFFECT PARAMETERS MEASURED (with observation intervals if applicable): the oxygen consumption was recorded for a period of ~10 min. Determination of oxygen was performed with multiple oxygen probes connected to a BlueBox (GO-Systemelektronik GmbH, Germany), a multichannel measuring and controlling system.

TEST CONCENTRATIONS
- Spacing factor for test concentrations: 3.2
- Range finding study
- Test concentrations: 10, 100, 1000 mg/L
- Results used to determine the conditions for the definitive study: yes
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
other: ELR50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Key result
Duration:
3 h
Dose descriptor:
other: NOELR
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
- Effect concentrations exceeding solubility of substance in test medium: no data
- The 3-h ELR10 = 335 mg T002326/L (estimation)
Results with reference substance (positive control):
3-h EC50 = 4.5 mg/L.
This is within the recommended range of 2-25 mg/L confirming suitability of the activated sludge used.
Reported statistics and error estimates:
The 3-h EC50 values were based on Probit Analysis.
The NOEC determination was based on the STUDENT-t test for Homogeneous Variances with a Bonferroni-Holm Adjustment in the final test, alpha=., one sided, smaller).
Validity criteria fulfilled:
yes
Conclusions:
An activated sludge respiration inhibition test (according OECD guideline 209) with activated sludge from a predominantly domestic sewage treatment plant resulted in a 3-h ELR50 > 1000 mg T002326/L. Therefore it is concluded that 1000 mg/L of the test substance did not have a toxic effect on the respiration rate of activated sludge micro-organisms in this study. The results of the study can be considered reliable without restriction.

Description of key information

In the test flasks dosed with the test substance, <10% respiration inhibition was observed at all the tested concentrations. The 3hour ELR50 for the test substance was determined to be >1000 mg/L. The 3hour NOELR was determined to be 1000 mg/L. Therefore it is concluded that 1000 mg/L of the test substance did not have a toxic effect on the respiration rate of activated sludge micro-organisms in this study.

Key value for chemical safety assessment

Additional information