Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN paragr. 32.4.1
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester

Test material

Constituent 1
Reference substance name:
Essential oil of Copaiba obtained from the exudate of Copaifera (Fabaceae) trees by distillation
EC Number:
946-913-6
Molecular formula:
Not applicable for UVCB Substance
IUPAC Name:
Essential oil of Copaiba obtained from the exudate of Copaifera (Fabaceae) trees by distillation
Test material form:
liquid
Remarks:
pale yellow liquid
Details on test material:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Obtained from sponsor, batch S-71699
- Expiration date of the lot/batch: 14 February 2019
- Purity test date: 14 February 2017

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature protected from light

Results and discussion

Flash point
Key result
Flash point:
108 °C
Atm. press.:
1 013.25 hPa

Applicant's summary and conclusion

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
the flash point of Copaiba Balsam oil is 108ºC at 1013.25 hPa.
Executive summary: