Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 617-898-0 | CAS number: 866462-52-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- April 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- The determination was carried out using a procedure designed to be compatible with that given in European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 016
- Report date:
- 2016
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: Guidance Document EUR 20268
- Version / remarks:
- Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).
- Deviations:
- no
- Principles of method if other than guideline:
- Sieve Screening : An aliquot (approximately 10 to 20 g) of test item was added to a 100 μm sieve fitted onto a receiver pan of known mass. A lid was then secured onto the sieve and the assembled apparatus placed on the sieve shaker for a period of approximately 30 minutes. The sieve shaker table, on which the sieve rests, had an inclination of 4.5°, a nominal rotation speed of 2.5 rpm and vibrated at approximately 300 oscillations/min with an approximately 4 mm amplitude. Following the shaking period, the mass of the receiver pan and collected test item was recorded and the percentage of test item with a particle size less than 100 μm calculated.
Second part : Cascade Impactor : An aliquot (approximately 3 g) of test item was introduced by aid of an anti-static weighing boat into the artificial throat of the cascade impactor. During the determinations, air was drawn through the cascade impactor by a vacuum pump at a flow rate of approximately 60 L/ min for approximately 30 seconds. The air flow enters the impactor through a throat and inlet tube and then accelerates through the multiple stages. At each stage one or more nozzles direct the particle-laden airstream into a collection cup. - GLP compliance:
- yes (incl. QA statement)
- Type of method:
- cascade impaction
- Type of particle tested:
- primary particle
- Type of distribution:
- mass based distribution
Test material
- Reference substance name:
- 617-898-0
- EC Number:
- 617-898-0
- Cas Number:
- 866462-52-4
- Molecular formula:
- C17 H21 N O5
- IUPAC Name:
- 617-898-0
- Test material form:
- solid: particulate/powder
- Details on test material:
- Off white powder
Constituent 1
- Specific details on test material used for the study:
- Batch 18108859
Sieving Apparatus (Screening Test) :
Instrument : Inclyno Sieve Shaker, Model No 1
Sieve : 100 μm stainless steel mesh (ISO 3310-1: 2000)
Cascade Impactor
Instrument : MSP Corporation, Marple Miller 160 Cascade Impactor
Particle size range : nominally 0.3 to 10 μm
Results and discussion
Particle size distribution at different passagesopen allclose all
- No.:
- #1
- Size:
- < 100 µm
- Distribution:
- ca. 52.2 %
- No.:
- #2
- Size:
- < 10 µm
- Distribution:
- ca. 3.65 %
- No.:
- #3
- Size:
- < 5.5 µm
- Distribution:
- ca. 0.6 %
Any other information on results incl. tables
Results of the sieving procedure are :
Mass of test item transferred to sieve : 12.56 g
Mass of test item passed through sieve : 6.55 g
Percentage of test item less than 100 μm : 52.2 %
(See complete report TN47PW particule size distribution attached)
Applicant's summary and conclusion
- Conclusions:
- Sampling for the cascade impactor determinations was performed by rolling the test item container for approximately 10 minutes then sampled from the top, middle and bottom.
Too few particles were of a size less than 10.0 μm to allow accurate assessment of the mass median aerodynamic diameter.
The inhalable fraction is defined as the mass fraction of particles which can be inhaled by nose or mouth, the thoracic fraction is defined as the mass fraction of particles that passes the larynx and the respirable fraction is defined as the mass fraction of particles that reaches the alveoli.
Percentage of test item with an inhalable particle size <100 μm : 52.2%
Percentage of test item with a thoracic particle size <10.0 μm : 3.35%
Percentage of test item with a respirable particle size <5.5 μm : 0.60%
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.