First-aid measures

Emergency measure - Inhalation: Remove peron from exposure. Clear nose, mouth and throat.
Rest and keep warm. If irritation develops, seek medical
attention.
Emergency measure - Eyes: Rinse thoroughly with a large amount of water for at least
10 minutes. If irritation develops, seek medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash thoroughly with soap and
water. If irritation develops, seek medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Use carbon dioxide, alcohol resistant foam or dry powder.

Product arising from burning: The substance is combustible and will burn if involved in a
fire, evolving noxious fumes (eg carbon and silicon oxides).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.


Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards, as
mentioned in section 2.3.10.


Absorb spillages of solutions with a suitable inert material
(eg. sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original substance containers.


Clean the spillage area with water and detergent.


Dispose of waste material in accordance with local
regulations.

Handling and storage

Handling: The substance should be stored, handled and used under
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.


Engineering controls are necessary to reduce exposure to the
substance.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be
used, it must be capable of adequately controlling exposure,
be suitable for the purpose, and conform to the appropriate
international or national standards, such as a dust mask
conforming to EN149 FFP1.

These measures should be regarded as a minimum.

Storage: Store in closed containers at ambient temperature.

Packaging of the substance and or preparation: 200 kg open top steel drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None which is hazardous.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: There will be no discharge to the environment. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration or at an authorised site as
special waste. In principle, it may be possible to recover
larger spillages of uncontaminated material for subsequent
use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is not
hazardous.

Industry - Possibility of destruction: controlled discharge: Not applicable.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg. carbon and
silicon oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.